TWO PHASE FLOW HEAT TRANSFER IN NUCLEAR REACTORS
WITH EMPHASIS TO TRANSIENT PHENOMENA
Introduction
Two phase flow heat transfer in light water cooled nuclear reactors
(LWR) is an important area of Nuclear Engineering.
The complex phenomena observed during both the steady state and especially
the transient operation of a LWR
necessitates, besides the theoretical, extensive experimental studies.
Theoretical studies of two phase flow phenomena are conducted
since 1978 in our Section and
numerical computer codes have been developed (
[1, 1986],
[7, 1991]).
Between 1987-1990 an experimental facility
was designed and constructed.
Thorough experimental studies of transient heat transfer phenomena
with emphasis the rewetting phenomena
is being conducted.
The Rewetting Phenomenon
All types of power-producing, water cooled nuclear reactors have coolant circuits
which operate at high pressures, ranging from about 70 bar in the boiling -water reactor
(BWR) and the steam-generating heavy-water reactor (SGHWR)
to 150 bar in the pressurised-water reactor (PWR). Any unexpected decrease
in coolant flow through a reactor core leads to serious consequence for the plant
as a whole. Such a drop in flow can be caused by anything from a leak in a small pipe
to the complete severance of a major coolant pipe wich could lead to a loss-of-coolant
accident (LOCA). An emergency core-cooling system (ECCS) should be operated
in this case in order to prevent the uncovered fuel elements from melting because
of fission product heating. The reestablishment of a cooling liquid film, or the
rewetting
of the overheated fuel elements is a process of particular importance
in the case of such an accident.
Nearly all two-phase flow regimes, pre-dry-out, dry-out and post-dry-out
may appear in the course of a rewetting process.
Several water experiments have been carried out to simulate the rewetting phenomenon
and to predict the liquid cooling film behaviour.
The temperature history of a position on a fuel element before and after the
ECCS activation has been experimentally and theoretically investigated.
At the beginning, the cooling has very little effect and hence the temperature continues to rise,
but with a lower rate, until it reaches a maximum that is called turn round temperature.
Then it starts decreasing slowly until a sudden temperature drop occurs.
The time at which this rapid temperature fall occurs is known
as the quench time. The turn round time, turn round temperature and quench time are
important quantities and numerous experiments have been conducted to measure them.
The Experimental Facility.
The test facility consists primarily of two fluid loops which supply the test section
independently with continuous flow of water and steam as can be seen in
the attached diagram.
A heating tank fitted with four electric immersion heaters (2x6,
2x12 kW), pressure, temperature and level controlled, is used as a
pressurizer and steam generator.
Heated liquid at saturation temperature is discharged from the bottom
of the heating tank to the test section via a magnetic flowmeter.
Steam leaves the test section to a five branch co-axial double pipe counterflow
condenseri and the condensate is accumulated in the holding tank.
The pressure in the holding tank is maintained at a pre-set value.
The liquid from the holding tank is pumped into the heating tank
by an automatically controlled centrifugal pump.
To control the flow of the heating tank, a portion of the discharged
liquid can return to the holding tank via a by-pass. The pump discharge line
to the holding tank is supplied with a non-return valve.
The desired limits of the liquid levels in the two tanks are maintained
with two automatic control level gauge systems, which control the supply
of electrical power to the immersion heaters and the pump.
Both tanks are supplied with spring safety relief valves which are
provided with discharge connections to outdoors sight glass level gauges and remote
level gauges.
The flow to and from the test section can be instantaneously cut-off by the
application of solenoid valves.
The main control and safety devices of the rig, as well as other monitor
instrumentation, is mounted on a panel.
The Test Section
The test section consists of a high pressure and temperature
ressistant glass tube with 25.4 mm inside diameter that allows
the visual observation of the studied phenomena. The tube
encloses a concentric electrically heated rod, inlet supply head
and outlet arrangement.
The heated rod was manufactured by "Hedin Co. Ltd" as follows:
on the outside surface of a stainless steel tube (12.7 mm OD), magnesia
powder filled, that accomodates a 4.5 kW heater tape, twelve
Iron-Constantan thermocouples were placed at different positions along the tube length.
Stainless stell wires were used to keep the thermocouples apart.
This structure was inserted in another stainless steel tube
(17.4625 mm OD) and then all this assembly was swaged down to 15.875 mm.
Thus, the heated rod consists of an indirectly heated
stainless steel tube (15.875 mm OD, 3.72 mm thick)
which is filled with magnesia powder.
Twelve thermocouples are embedded inside the
stainless steel sheath and an accurate indication of the wall
temperature at different points along the length of the rod is ensured.
The heated part of the rod is 1.016 m and there is a 0.3302 m cold length
at each end of the rod. Thermocouples TC1 and TC12 which are positioned in the
cold ends of the rod, are used to measure the temperature near the "O" ring
seals at the inlet and outlet of the test section. Thermocouple TC11 is
connected to a thyristor unit which regulates the power supply necessary
to preheat the rod to a given temperature set by a "GULTON" temperature
controller. The thermocouple TC11 is connected to a "GOULTON" trip relay system
(ON-OFF controller) which will cut-off the power to the test section heater,
if the thermocouple accidentally exceds a pre-selected temperature on the controller dial.
This is a safety precaution against overheating. Any of the test section
thermocouples can be used for experimental observations, provided that
it is connected with an appropriate compensating lead to a data
acquisition system, as will be discussed later.
The inlet supply head of the test section is designed to supply the heated rod
with a uniform falling liquid film, which is discharged through an orifice.
Steam is supplied to the test section through a porous disc situated at the side of
an annular space between the glass tube and the rod, such that it does not
disturb the liquid falling film at its inlet to the test section.
The lower end of the glass tube is connected to an arrangement by which
steam and liquid can leave the test section separately.
Data Acquisition and Analysis
The whole facility have been supplied with transducers and actuators
in order to operate entirely automatic.
There are about 50 temperature, pressure, liquid and vapour flowrate,
level and bi-stable condition indicators and sensors
and about 40 controllers around the loop.
Pressure inside the heating tank and at the inlet and outlet of test
section is been monitored by 3 pressure transducers.
Liquid mass flowrate at the inlet of test section is being
continuously measured by a very accurate Magnetic Flowmeter.
The analog signals from the transducers
are multiplexed and then led to an
analog-to-digital converter
directly connected on the bus of an 80386/40MHz PC IBM-compatible.
A FORTRAN program, calling ASSEMBLY routines, user friendly menu-driven,
is monitoring the facility and performs data acquisition with rates of up to 100
samples per second.
The data collected are automatically
transfered via a Local Area Network to an HP-9000/370 UNIX-Based mini
computer where specific fortran programs calling computational and
graphical routines display and print suitable diagrams describing
the phenomena.
Cladding temperature history and wet-front propagation
A representative diagram
of a collected-data processing of a rewetting experiment in
atmospheric conditions (1 bar pressure, 550 °C initial wall
temperature, 0 K subcooling and without steam flowrate) is been attached.
This diagram clearly demonstrates the temperature profile during rewetting
of each one of the twelve thermocouples in the rod.
A method was also introduced to calculate the wet front position
along the rod.
Experiments have been run to investigate
the wet front propagation under pressures 1-7 bars for various initial
wall temperatures, 0 K subcooling, minimum steam flowrate
and liquid flowrate of 1 L/min.
Finally, a simulation correlation proposed in
[1, 1986] was extrapolated
down to 1 bar with data produced from this facility.